مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801An Overview of the Hydrology of the Zayandeh Rud Basin, Iranسیمای کلی هیدرولوژی حوضه آبخیز زایندهرود2132515FAحمیدرضا سالمیعضو هیأت علمی مرکز تحقیقات کشاورزی و منابع طبیعی استان اصفهانهاموندمورای راستعضو مؤسسه بینالمللی مدیریت منابع آب، کلمبو، سریلانکاJournal Article20031012This paper provides an overview of the hydrology and water use in the Zayandeh Rud basin based on the data available over the 11- years period 1988-1998. The inflows into Chadegan reservoir, the releases from the reservoir, and the extractions along the river for irrigation and other purposes are considered, and a rapid water balance of the basin is performed. Inflows to the Chadegan reservoir, which serves to collect and regulate the runoff from the upper catchment of the basin to better meet the downstream water requirements for irrigation, urban and industrial uses, follow a regular pattern with moderate variability. But the limited year-to-year storage in the reservoir makes the basin vulnerable to prolonged periods of drought. Water releases from the Chadegan reservoir also show a predictable pattern, with the only deviations occurring during flood events. There is a high reliability of meeting the water requirements during periods of peak demand. But releases during the winter months, at the end of the irrigation season, are lower and more variable. This results in low discharges in the Zayandeh Rud and reduced water quality, especially in the lower reaches of the river. A simple water-balance approach was used to estimate the proportion of return flows in the basin. An average annual value of 30% was obtained, with the magnitude of return flows being particularly important in the lower reaches of the basin. But more investigation, especially including groundwater and water quality aspects, needs to be carried out before a definitive value can be advanced. Given the limited supply of fresh water in the Zayandeh Rud basin, further water resources development and water management improvements can only be envisaged in there is scope for real water savings in the basin. This can be assessed if a basin-wide approach, leading to a good understanding of water use (and reuse) at the farm, system and basin levels, is adopted.در این مقاله به بررسی کلی خصوصیات هیدرولوژیکی و استفاده از آب در حوضه زایندهرود براساس آمار موجود در دوره یازده ساله (1998-1987) پرداخته شده است. در این راستا جریان ورودی به دریاچه سد، جریان خروجی از دریاچه و آبگیریها در طول مسیر رودخانه، به منظور آبیاری اراضی کشاورزی و دیگر مصارف مورد بررسی قرار گرفته و یک بیلان آبی اجمالی در سطح حوضه ارائه شده است. نتایج نشان میدهد که جریانهای ورودی به دریاچه، نیاز آبیاری، شرب و بخش صنعت را در پایین دست تأمین نموده و از یک الگوی منظم با تغییرات بسیار کم تبعیت مینماید؛ اما ذخیره سالیانه سد محدود بوده به طوری که در طول دورههای خشکسالی طولانی، حوضه را آسیبپذیر نموده است. همچنین روند آب خروجی از سد زایندهرود، یک الگوی قابل پیشبینی را به جز در مواقع سیلابی نشان میدهد. به نظر میرسد، اعتماد و درصد اطمینان بالایی در تأمین نیازهای آبی، در دوره تقاضای حداکثر وجود دارد؛ ولی آب خروجی در ماههای فصل زمستان و در پایان فصل آبیاری، دارای میزان پائین و با تغییرات بالا میباشد که در نتیجه بده رودخانه کم و کیفیت آب به ویژه در پایاب رودخانه پایین میآید. یک بیلان آبی ساده، نسبت جریان آب برگشتی در حوضه (میانگین سالیانه) را 30 درصد تخمین زده است. میزان حجم آب برگشتی به ویژه در قسمتهای پایین دست حوضه، بسیار مهم است. البته یک ارزیابی دقیقتر با در نظر گرفتن پارامترهای آب زیرزمینی و کیفیت آب، قبل از نتیجهگیری قطعی، ضروری به نظر میرسد. با فرض محدودیت تأمین آب با کیفیت بالا در حوضه آبریز زایندهرود، اگر امکان صرفهجویی واقعی آب در حوضه، وجود داشته باشد، میتوان به توسعه منابع آب و اصلاح مدیریت این منابع دست یافت. از این رو در سطوح مزرعه، شبکه و حوضه درک قابل قبولی در مورد کاربرد آب و استفاده مجدد آب ضروری استhttps://www.wwjournal.ir/article_2515_c4c80895381471babe2bab18deec03ee.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801Application of Self Cleaning Rapid Sand Filter in Water Treatmentکاربرد صافی شنی تند خود شست و شو در تصفیه آب14222516FAعلیرضا رحمانیاستادیار گروه بهداشت محیط- دانشکده بهداشت- دانشگاه علوم پزشکی همدانJournal Article20030916Rapid sand filter is one of the most important units in the water treatment plants. It has some difficulties in operation such as backwashing. For the solving of this problem a rapid sand filter has designed and built with the self-cleaning backwashing system. This system consist of 3 main constituents; one galvanized siphon and two galvanized steel tanks. One of them is used for filtration and the other used for the storage of filtrated water in elevation for backwashing the system. Water enter from upside of the filter through the inlet pipe, and collected from the under drainage pipe. Then filter water conduct to the storage tank and exit from outlet pipe. In the beginning, the head loss was low, but because of bed clogging by suspended solids, it increases gradually to the designed head loss (1.2m). Then the system is outed of the service automatically and the backwash is began. The main data for the design of system selected from the hydraulic rules of siphons and rapid sand filter criteria. After essential calculations it was constructed and was started operation. For the hydraulic studies a known volume of storage tank was selected and the time needed for the fill (in filtration stage) and empty (in backwash stage) of water volume with volumetric method were measured. In hydraulic studies the filter surface rate (SOR) was selected about 5-7.5m<sup>3</sup>/m<sup>2</sup>/hr (1.39-2.08 lit/sec) and the flow of water in siphon, during the backwashing was measured 8.7 lit/sec. It can be seen that the siphon passes 4-6 times the inlet raw water thus a negative pressure will created in the siphon which causes the water above the sand bed to be discharged automatically and rinse water from elevated tank flow under the sand bed and back wash it. So according to this study self cleaning rapid sand filter is very useful for water filtration, especially in small population community. The construction of system is rapid, simple and economic. یکی از مهمترین واحدهای یک تصفیهخانه آب، صافی شنی تند میباشد که بهرهبرداری از آن به دلیل مرحله شست و شوی معکوس دارای مشکلاتی است. در این طرح تحقیقاتی، برای حل مشکل یک صافی شنی تند با سیستم شست و شوی معکوس خودکار، طراحی و ساخته شد. سیستم شامل سه قسمت اصلی لوله سیفون برای شست و شوی معکوس و دو مخزن گالوانیزه میباشد. مخزن اول به عنوان صافی و مخزن دوم برای ذخیرهسازی آب فیلتر شده (در رقوم ارتفاعی 2 متر) میباشد. آب خام ورودی به صافی پس از فیلتر شدن به مخزن ذخیره منتقل شده و پس از تغذیه آن از سیستم خارج میگردد. در ابتدای صافیسازی، افت فشار صافی پایین میباشد، ولی به دلیل گرفتن بستر توسط جامدات معلق، کم کم افزایش یافته و زمانی که به حد طراحی شده )1/2 متر( رسید، شست و شوی معکوس سیستم به صورت خودکار آغاز میگردد. اطلاعات اصلی برای طراحی سیستم از هیدرولیک سیفونها و معیارهای طراحی صافی شنی تند انتخاب گردید. بعد از محاسبات لازم، صافی ساخته شده و در مدار بهرهبرداری قرار گرفت. برای مطالعات هیدرولیکی، حجم مشخصی از مخزن ذخیره در نظر گرفته شد و زمان مورد نیاز برای پر شدن این حجم توسط آب (در مرحله فیلتراسیون) و تخلیه آن (در مرحله شست و شوی معکوس) اندازهگیری شد. در مطالعات هیدرولیکی بار سطحی فیلتر (SOR) در حدود (l/s 2/08-1/39) m<sup>3</sup>/m<sup>2</sup>/hr 5/7-5 انتخاب شده و جریان آب در سیفون در طی شست و شوی معکوس l/s8/7 اندازه گیری شد. سیفون در حدود 4 تا 6 برابر جریان آب ورودی را از خود عبور میدهد. بنابراین یک فشار منفی در سیفون ایجاد میشود که باعث میگردد آب بالای بستر به صورت خودکار تخلیه شده و آب آبکشی بستر از طریق مخزن ذخیره که در ارتفاع واقع شده به زیر بستر منتقل و آن را شست و شوی معکوس نماید. بررسی سیستم نشان میدهد که از این سیستم، میتوان به راحتی برای صاف کردن آب به خصوص برای اجتماعات با جمعیت پایین استفاده نمود. ساخت سیستم، سریع، ساده و ارزان بوده و به دلیل عدم کاربرد هرگونه قطعه مکانیکی در آن و همچنین عدم نیاز به کاربر به راحتی قابل استفاده در شرایط مختلف میباشد.https://www.wwjournal.ir/article_2516_b46a90696e9d6c5ee776b51e80da389d.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801Bioactivity Improvement in Activated Sludge Treatment of Petroleum Refinery Wastewaterبهینهسازی فعالیت میکروارگانیسمها در تصفیه بیولوژیکی فاضلابهای نفتی پالایشگاه تهران23282517FAپروین ناهیدمربی، مرکز تحقیقات مهندسی بیوشیمی و محیط زیست، دانشگاه صنعتی شریفاخترالملوک کاظمیاستادیار، مرکز تحقیقات مهندسی بیوشیمی و محیط زیست، دانشگاه صنعتی شریفJournal Article20031201
شماره 50- سال 1383 آب و فاضلاب
Petroleum refineries generate large amounts of wastewater with high concentrations of hazardous contaminants. The conventional treatment method is a biological treatment process preferably the activated sludge system. In this system some organic compounds can be toxic or inhibitory to some organisms above certain critical concentrations and cause the growth rates to decline, such as Toluene and Phenol. There are also accelerating materials to improve the biological treatment efficiencies, such as Methanol, Glucose etc. In the present work the effects of Phenol, Glycerine and Maltose on the performance of the process were investigated. The Phenol concentrations up to 100ppm did not show any inhibitory effects on the COD percent removal; however higher concentrations reduced the process treatment rate. Glycerine concentration., between 0-200 ppm caused increase in COD removal from 57% to 79%. Maltose gave similar results to Glycerine which has been fully discussed.پساب پالایشگاههای نفت، در زمره مهمترین پسابهای آلاینده محیط زیست میباشند. برای تصفیه این گونه پسابها، اغلب از سیستمهای بیولوژیکی هوازی مثل لجن فعال استفاده میشود. درصد حذف مواد آلاینده در این سیستمها، بستگی به میزان فعالیت میکروارگانیسمهای موجود دارد. برخی از مواد مثل متانول، گلوکز و غیره باعث تسریع و بهبود این فعالیت میشوند و بعضی دیگر حالت بازدارنده دارند، مثل تولوئن، فورفورال و فنل. در این پروژه دو ماده گلیسیرین و مالتوز به عنوان سرعت دهنده تصفیه و فنل به عنوان بازدارنده، روی فاضلاب پالایشگاه نفت تهران در مقیاس آزمایشگاهی، مورد بررسی قرار گرفت. مبنای سنجش، آزمایش COD و کدورت سنجی بود. نتایج حاصل نشانگر این است که با افزودن گلیسرین به سیستم، درصد حذف COD به شدت افزایش مییابد. به طوری که در اثر افزایش غلظت گلیسیرین از صفر به ppm200 ، راندمان حذف COD از %57 به %79 میرسد. کدورت فاضلاب خروجی نیز از غلظت ppm400-0، از NTU0/057 به NTU0/032 میرسد که نشانگر %50 حذف مواد جامد معلق میباشد. سمیت فنل با افزایش غلظت آن تا ppm100 در زمانهای ماند کوتاه حدود 6/5 ساعت تأثیر زیادی روی عملکرد میکروبها ندارد و درصد حذف COD از %40 به %59 میرسد. ولی از این غلظت بیشتر خاصیت سمی آن آشکار میشود. در مورد مالتوز نیز نتایجی مشابه با گلیسرین مشاهده شدhttps://www.wwjournal.ir/article_2517_b8e9c0a54631dded2815a18d178134d1.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801Survey of Chemical Quality and Fertilizer Value of Vermicomposted Municipal Wastewater Sludgeبررسی کیفیت شیمیایی و ارزش کودی ورمی کمپوست تهیه شده از لجن فاضلاب شهری اصفهان29332518FAعبدالرحیم پرورشعضو هیأت علمی گروه مهندسی بهداشت محیط دانشگده بهداشت دانشگاه علوم پزشکی اصفهانحسین موحدیان عطارعضو هیأت علمی گروه مهندسی بهداشت محیط دانشگده بهداشت دانشگاه علوم پزشکی اصفهانلیلا حمیدیانکارشناس ارشد شرکت آب و فاضلاب استان بوشهرJournal Article20031010Using of organic waste resources especially municipal wastewater sludges for improvement of agricultural soils’ fertility is increasing , but in order to decrease environmental and health risks sludge must be stabilized before using in farms. Nowadays, vermicomposting process has been considered for stabilizing organic wastes. As, there is contravercial reports about concentration of nutrients (P,.K.N), organic matters and C/N ratio in vermicomposts, this research study is performed to determine concentration of nutrients organic matters and C/N ratio in vermicomposts derived from municipal wastewater sludge The concentration of nutrients in manure and vermicompost was compared with each other. شماره 50- سال 1383 آب و فاضلاب Eighty five percent of dewatered raw sewage sludge and %15 bulking agent were mixed to provide earhworms’ food for a one month period. Concentrations of volatile orgainic matters, total nitrogen, total phosphorous, total potassium, Ash and pH in initial substrate and vermicomposted sludge were determined by dry agitation., macrokageldal, colorimetery, flamephotometery, Gotas, modifled Burian and Erhart methods, respectively. Concentrations of organic matter, nitrogen phosphorous, potassium , pH and C/N ratio in vermicomposted sludge were %36.42 , %1.04 , %0.11 , %0.62 , 7.5 and 22.62 respectively. The obtained vermiocompost is a suitable organic amender for fertilizing of agricultural soils.استفاده از منابع مختلف مواد زائد آلی به ویژه لجن فاضلاب شهری و خانگی، برای بهبود حاصلخیزی خاکهای کشاورزی رو به گسترش است؛ اما برای کاهش خطرات بهداشتی و محیطی لجن، بایستی قبل از کاربرد بر روی زمین آن را تثبیت نمود. امروزه فرایند کمپوست به کمک کرمهای خاکی، برای تثبیت مواد زائد مورد توجه قرار گرفته است. از آن جا که گزارشهای متناقضی راجع به مقادیر مواد مغذی (K,P,N) در ورمی کمپوستها وجود دارد، این تحقیق به تعیین مقادیر مواد مغذی (K,P,N) و مواد آ لی و نسبت C/N ورمی کمپوست حاصل از لجن فاضلاب شهری میپردازد و مقادیر مواد مغذی در کودهای دامی و ورمی کمپوست حاصل را با یکدیگر مقایسه مینماید . غذای مورد نیاز یکماه کرمهای خاکی، از اختلاط 85درصد لجن فاضلاب خام آبگیری شده و 15درصد عامل حجیم کننده، آماده شد. مقادیر مواد آلی فرّار ، نیتروژن ، فسفر کل، پتاسیم کل، خاکستر و pH موجود در سوبسترای اولیه و ورمی کمپوست حاصل به ترتیب به روش سوزاندن خشک، ماکروکجلدال، کالری متری، فلیم فتومتری، گوتاس و روش اصلاح شده ارهارت و بورین تعیین گردیدند. مقادیر مواد آلی ورمی کمپوست، نیتروژن، فسفر، پتاسیم، pH و نسبت C/N به ترتیب 36/42، 1/04، 0/11، 0/62 ، 7/5 و 22/62 درصد بود. ورمی کمپوست حاصل، اصلاح کننده آلی مناسبی برای بهبود حاصلخیزی خاکهای کشاورزی میباشد.https://www.wwjournal.ir/article_2518_76e9b73c8d79dc07843ee3686e50a6d3.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801An Investigation on the Industrial Wastewater in Tehran Provinceبررسی وضعیت فاضلابهای صنعتی- تولیدی در صنایع استان تهران34442519FAعلی ترابیاندانشیار دانشکده محیط زیست دانشگاه تهرانمریم مهجوریکارشناس ارشد محیط زیستJournal Article20030711During 1994 to 1999 a research program titled “A qualitative and quantitative review of industrial wastewater in Tehran province” was done . This article presents the most important results obtained from this study . The research covered 330 food , textile , chemical , and Materials (Metal and liquid materials) factories . Completing of the questionnaire , sampling from the wastewater and analyzing have been done for 5 years . The results show that completely wastewater treatment in food , textile and metal industries were done in 8% , 18% and 17% of units respectively . In chemical industries for major groups include pharmaceutical , soap and detergent , pulp and paper , and paint industries were studied . In pharmaceutical and pulp and paper industries , there were only one factory in each group which were doing a complete treatment , and in detergent and paint industries there were no complete treatment at all . Maximum discharge of wastewater in food and textile industries were into surface waters . They were 62.4% and 48.8% respectively . But mainly wastwater discharging in metal and liquid materials industries were into ground waters which were 86% and 83% respectively .طی سالهای 1373 تا 1378 یک طرح تحقیقاتی تحت عنوان “مطالعه و بررسی فاضلابهای صنعتی استان تهران” به اجرا در آمد که در مقاله حاضر مهمترین نتایج این تحقیق ارائه شده است. در این طرح، صنایع غذایی، نساجی، شیمیائی، فلزی و تولید محصولات کانی غیرفلزی مورد مطالعه قرار گرفتند، که شامل 330 محل مراجعه بودند. روش اجرای تحقیق به صورت تکمیل پرسشنامه و نمونهبرداری از فاضلاب بود. نتایج و اطلاعات به دست آمده نشان میدهد که مثلاً برای صنایع غذایی ، نساجی و فلزی به ترتیب %8 ، %18 و %17 تصفیه به صورت مطلوب انجام میگیرد و به استانداردهای تخلیه توجه شده است. در بخش صنایع شیمیائی، چهار گروه عمده صنایع دارویی، صنایع تولید محصولات بهداشتی- آرایشی، صنایع تولید رنگ و صنایع کاغذسازی بررسی شدند که در میان صنایع دارویی و کاغذسازی برای هر کدام، تنها یک کارخانه تصفیه کامل انجام میداد. اما هیچکدام از صنایع تولید محصولات بهداشتی- آرایشی و صنایع تولید رنگ، دارای تصفیهخانه کامل نبودند. حداکثر تخلیه پسابها در صنایع غذایی و نساجی به ترتیب %62/4 و %48/8 به آبهای سطحی و در صنایع فلزی و تولید محصولات کانی غیرفلزی به ترتیب %86 و %83 به آبهای زیرزمینی بود.https://www.wwjournal.ir/article_2519_937d1d26b5705d96c5478460194c5196.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801Application of Modflow in Groundwater Management and Evaluation of Artificial Recharge Project of Ab-barik Aquifer (Bam)بکارگیری مدل Modflow مدیریت بهرهبرداری از آبهای زیرزمینی و ارزیابی عملکرد طرح تغذیهی مصنوعی دشت آب باریک بم45582520FAهمایون کتیبهاستادیار دانشکده معدن، دانشگاه امیرکبیر، تهرانسعید حافظیکارشناس ارشد دانشکده معدن، دانشگاه امیرکبیر، تهرانJournal Article20030927This study is an attempt in groundwater modeling of Ab-barik aquifer (Bam, Iran), in order to asses the artificial recharge project and the future situation of the aquifer. Studies show that the discharge of the aquifer has exceeded the recharge, especially during the 1980-1990. The water table in March 1985 has dropped about 10m as compared with March 1973. Studies indicate that the drawdown of the free surface will continue in the future so that in March 2004, the drawdown will be about 18m as compared with the March 1973. Also it was found that despite the artificial recharge of the aquifer (started in 1996), the drawdown has been continuing. Modeling has showed that artificial recharge project has caused 12.6 mm3 recharge into the aquifer annually, during 1996-1999.این مقاله کوششی است در راستای به کارگیری مدلسازی جریانهای آب زیرزمینی به منظور پیشبینی وضعیت آیندة آبخوان آب باریک بم و نیز ارزیابی کمّی تأثیر پروژه تغذیة مصنوعی این آبخوان. مطالعات نشان میدهند که میزان برداشت از ذخایر این آبخوان، به خصوص از سالهای دههی شصت شمسی به بعد، بیش از میزان تغذیة آن بوده است. این امر موجب افت سطح ایستابی آبخوان میشود به گونهای که در اسفند ماه 1364نسبت به اسفند ماه 1352 در حدود ده متر افت در سطح ایستابی مشاهده میشود. همچنین شبیه سازی آبخوان مؤید آن است که روند افت سطح ایستابی کماکان ادامه خواهد داشت، به طوری که در اسفند ماه 138٣ میزان افت نسبت به اسفند ماه 1352 در حدود 18 متر خواهد بود. مطالعات نشان میدهند که روند افت، علیرغم شروع به کار طرح تغذیة مصنوعی آبخوان (از سال 1375)، ادامه خواهد داشت. همچنین شبیهسازی نشان داده است که در اثر پخش سیلاب (به منظور تغذیة مصنوعی)، به طور متوسط طی سالهای 78 ـ 1375 به میزان 12/6 میلیون متر مکعب آب به آبخوان افزوده گردیده که این میزان تغذیة مصنوعی هر چند از نرخ افت سطح ایستابی کاسته است اما قادر به توقف روند افت سطح ایستابی آبخوان آب باریک بم نبوده است.https://www.wwjournal.ir/article_2520_d95af9e93e7941030f345150fe3a88a4.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801The Use of Anaerobic Baffled Reactor (ABR) for Industrial and Municipal Wastewater Treatmentبررسی ویژگیهای رآکتور بافلدار بیهوازی (ABR) در تصفیه پسابهای صنعتی و شهری59622521FAجواد امیرفخریدانشجوی کارشناسی ارشد مهندسی شیمی دانشگاه صنعتی شریفجلالالدین شایگاندانشیار دانشکده مهندسی شیمی و نفت دانشگاه صنعتی شریفJournal Article20031007 شماره 50- سال 1383 آب و فاضلاب This paper reviews the recent advances in the development of ABR, which is one of the new types of anaerobic reactors capable of handling different kinds of industrial and municipal wastewaters. This reactor consists of some compartments in which environmental conditions such as pH and temperature or toxic material are stabilized in first compartment. Therefore, methanogenic bacteria that are very sensitive to environmental conditions can grow easily in the next compartment. An important property of this reactor is the low hydraulic retention time (HRT) of wastewater, that reduces the reactor volume and increases solid retention time (SRT). Also, the reactor is more stable to hydraulic and organic load shocks and there is no need to gas-solid separation devices. There is indeed, ability to separation of methanogenic and acidogenic phases. Economical studies show that these systems are also cost effective.The ABR reactor has shown good performance in the treatment of low strength and low temperature wastewater and those containing sulfate.رآکتورهای ABR از چندین اتاقک تشکیل شدهاند که این ویژگی باعث میشود مواد سمی و ...... با تغییرات در شرایط محیطی مثل pH و دما در اتاقک اول متعادل شده و در نتیجه باکتریهای متانزا که نسبت به شرایط محیطی متغیر، بسیار حساس هستند، به راحتی در اتاقکهای بعدی رشد نمایند. از مهمترین ویژگیهای این رآکتور میتوان به پایین بودن HRT و در نتیجه حجم کمتر، زیاد بودن SRT، پایداری نسبت به شوکهای هیدرولیکی و آلی و همچنین توانایی تفکیک فازهای اسیدوژن و متانوژن اشاره کرد. توانایی در تصفیه فاضلابهای حاوی سولفات و همچنین پسابهایی که به سختی تشکیل گرانول میدهند و در نتیجه تصفیه آنها با رآکتور UASB مشکل است از دیگر ویژگیهای این رآکتور میباشد.https://www.wwjournal.ir/article_2521_a942cb967709d9219cfbdb952374006c.pdfمهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593615220050801Distribution of Sewer Diameters in Wastewater Collection Based on Population Size for Urban Areas in Iranبرآورد توزیع قطر برحسب جمعیت در شبکههای جمعآوری فاضلاب شهرهای ایران63652522FAاحمد رجبیزادهعضو هیأت علمی گروه بهداشت محیط، دانشکده بهداشت دانشگاه علوم پزشکی کرمانمحمدرضا افسرینژادعضو هیأت علمی بخش مهندسی مکانیک، دانشکده فنی دانشگاه شهید باهنر کرمانJournal Article20030824This research was performed to elicit the distribution of sewers diameter in terms of population by means of information collection via consultant engineering and urban water and wastewater engineering companies. Based on obtained data in the cities with population fewer than 100/000 the highest percentage of diameter distribution was 79.12% for 200mm pipe and the lowest was 0.06% for 900mm pipe. In the cities with population between 100000 and 500000 the highest percentage of diameter distribution was found 56.67% for 200mm pipe and the lowest was 0.12% for 900 mm pipe. In the cities with population of 500000 and more the highest percentage of diameter distribution was 59.67% for 200mm pipe and the lowest was 0.19% for 900mm pipe. Without population factor the highest percentage of diameter distribution was 60.73% for 200mm pipe and the lowest was 0.131% for 900mm pipe.براساس نتایج به دست آمده، برای شهرهای با جمعیت کمتر از یکصد هزار نفر، بیشترین درصد توزیع قطر مربوط به لوله با قطر 200 میلیمتر با توزیع %79/12 و کمترین آن مربوط به لوله با قطر 900 میلیمتر با توزیع %0/06 میباشد. در شهرهای با جمعیت بیشتر از یکصدهزار نفر و کمتر از پانصد هزار نفر، بیشترین درصد توزیع قطر مربوط به لوله با قطر 200 میلیمتر با توزیع %56/67 و کمترین آن مربوط به لوله با قطر 900 میلیمتر با توزیع %0/12 میباشد. در شهرهای با جمعیت پانصدهزار نفر و بیشتر، بالاترین درصد توزیع قطر مربوط به لوله با قطر 200 میلیمتر با توزیع %59/64 و کمترین آن مربوط به لوله با قطر 900 میلیمتر با توزیع %0/19 میباشد. در صورت عدم دخالت فاکتور جمعیت، بیشترین درصد توزیع مربوط به لوله با قطر 200 میلیمتر با توزیع %60/73 و کمترین آن مربوط به لوله با قطر 900 میلیمتر با توزیع %0/131 میباشد.https://www.wwjournal.ir/article_2522_424b46fbc997d2c7a90c67525408ba9d.pdf